This eliminates the need for wrapping the bare wire around the screws. Most newer plugs have a clamping connection that the wire slides straight into before tightening the screw. The new male or female plug will usually have an indicator line on it to show how much insulation to strip for an optimum connection. Double-check the connections for tightness by pulling gently on each wire. The ground screw may be marked with green coloring, but in any case, it is always connected to the U-shaped ground prong on the plug. Wrapping the wire clockwise ensures that the wire loop tightens around the screw as the screw is tightened.Ĭonnect the white (neutral) wire to the silver terminal, and connect the green (ground) wire to the ground screw, using the same technique. Make sure that no stray wires are sticking out from the connection. There should be a way to splice it that is both strong and watertight. I've read that it's not advisable to splice an extension cord, but this is about 12 gauge and almost new. Many new plugs have slots to insert the wire. Cutting some wood near the house with the electric saw, a quick spark, and alas, a damaged extension cord. Safely Splicing 220 Volt Electrical Wires and Cables If the original 8/3 cable is fed from the main electrical panel and the neutral wire of the original cable is insulated (it should be), then yes you can bond both the new cables neutral and the ground wires together with the old cable’s insulated neutral wire. Wrap the bare end of the black (hot) wire clockwise around the brass terminal. Using a screwdriver, loosen the terminal screws on the plug. No don’t splice an extension cord, and a15 amp cord is not good for anything that says 20A on it. The Spruce Home Improvement Review Board.
SPLICE EXTENSION CORD CODE
Printing only pursuant to Labor Code 142.3(a)(3) (Register 2008, No. Note: Authority cited: Section 142.3, Labor Code. That 9.99 cord you bought at Walmart isn’t worth your insurance company not paying out when your house burns down because you didn’t splice it properly. (g) A box or fitting shall be installed at each connection point, outlet, switch point, or junction point. I have millions of dollars worth of service cord (what garden variety grounded extension cords are made of) where I work and yes we splice them.

Cables and mats shall be arranged so as not to present a tripping hazard. (f) Flexible cords and cables run on the ground, where accessible to the public, shall be covered with approved nonconductive mats. Each extension cable splice kit consists of 3 butt splice connectors that are crimped onto the inner wires, and a waterproof outer cylindrical shell with 2. (e) Wiring for an amusement ride, attraction, tent, or similar structure shall not be supported by another ride or structure unless specifically identified for the purpose. Open the replacement plug so you can reach the terminal screws inside.
SPLICE EXTENSION CORD HOW TO
Connectors and cable connections shall not be placed in audience traffic paths or within areas accessible to the public unless guarded. Steps on How to Replace and Wire a Plug: Step 1: Cut the Old Plug and Slice the Jacket. Cord connectors shall not be laid on the ground unless listed for wet locations. (d) Flexible cords and cables shall be continuous without splice or tap between boxes or fittings. (c) Open conductors are prohibited except as part of a listed assembly or festoon lighting installed in accordance with Article 8, Outdoor Wiring. Please do all three of these if you plan to follow my procedure. The shrink tubing around the entire joint was not installed. I have not soldered nor insulated the Western Union splices. Sparber Protected by Creative Commons.2 There are a few critical things missing in this picture3. (b) Single conductor cable shall be size No. One Way1 To Splice an Extension Cord, Version 3.0 By R. When used outdoors, flexible cords and cables shall also be listed for wet locations and shall be sunlight resistant. Legally, splices can only be inside junction boxes. (a) Flexible cords and cables shall be listed for extra-hard usage. So heres how you handle 'the cord is too short'. Carnivals, Circuses, Fairs, and Similar Events Return to index

Low-Voltage Electrical Safety OrdersĪrticle 84. In this video, I show you how to fix an extension cord using heat shrink tubing and butt splices.This will work on just about any flexible cord, and will pre.